Powerware 9390

Powerware 9390 -- 40kVA to 160kVA
Product Summary
Built upon 40 years of power management experience,
performance and continuous innovation, the Powerware 9390 provides
the best combination of power performance, battery management,
scalable architecture, flexibility, power density, and warranty and
service.
The Powerware 9390 is designed to meet the current and future
power protection requirements of data centers, manufacturing
operations, medical facilities and other large-system applications.
That’s why Powerware conducted extensive customer research to help
create a UPS that would set the pace for three-phase power
protection. The result is a UPS that combines technical innovation
with a rich feature set to provide a best-in-class power protection
solution.
Features and Benefits
 |
Provides unmatched power performance for efficiency, input current
harmonic distortion (THD) and power factor |
 |
Scalable for capacity and redundancy to meet present and future
power needs
|
Unmatched Power Performance
 |
High efficiency of 94 percent reduces total cost of ownership
by reducing cost of power to support protected loads |
 |
Low total input harmonic current distortion (THD) of less than 4.5
percent enhances compatibility with upstream power systems,
especially generators |
 |
Input power factor of 0.99 minimizes auxiliary generator sizing
requirements and provides more power to unity power factor servers
|
 |
Output power rated at 0.9 power factor accommodates high power
factor load requirements |
 |
Double-conversion design offers the highest protection possible |
Enhanced Scalability
 |
Utilizes Powerware’s Hot Sync technology to parallel for capacity
and redundancy |
 |
Up to four (4) UPS modules can be paralleled without a tie cabinet,
while a total of eight (8) modules can be paralleled (providing a
total capacity of 1280 kVA) by using a tie cabinet |
Best Total Battery Management
 |
Extends battery life and optimizes battery recharge time via
patented Advanced Battery Management technology |
 |
Integrated battery management system tests and monitors battery
health |
 |
Optional temperature-compensated charging monitors battery
temperature and extends battery life |
 |
Variable battery buss matches battery capacity to exact customer
runtime |
 |
Enables remote monitoring of the UPS and battery system |
Flexible Installation and Serviceability
 |
Reduces installation time and costs with small footprint and
flexibility to install against walls, using top- or bottom-entry
cabling |
 |
Front-panel access for all services and operation increases
serviceability and reduces repair time |
Superior Warranty and Service
 |
Features a two-year limited factory warranty (parts and labor) |
 |
Service protection package includes Start-Up service, a UPS
Performance Check, two years of battery replacement labor coverage*,
and two years of web remote monitoring of both the UPS and batteries
|
* Batteries warranted by the battery manufacturer and not by
Powerware.
| Rating: |
30-160kVA |
| Voltage: |
Standard: 208/208,
400/400, 480/480
Optional: 600/600, 600/208,
480/208 |
| Frequency: |
45-65 Hz |
| Topology |
Online |
For
more information on the Powerware
9390,
contact your nearest
National Power sales representative. |

Sleek Chassis Enhances
you Datacenter

LCD Screen Provides Intuitive Menu

X-Slot Architecture Enables Connectivity
via SNMP, TCP/IP, Modbus, and More!
|